This dialog box allows the user to define the turbulence/friction properties and 3-D layer data.

 

The upper table is used for the turbulence/friction properties. For each element type the user must define:

1               The horizontal eddy coefficient.  Actual number entered depends on the horizontal turbulence method used (see user instructions)

2               The vertical eddy coefficient

3               The horizontal diffusion coefficient.  Not shown on the page but is an additional column on the right hand side

4               The vertical diffusion coefficient

5               The Manning/Chezy coefficient.  Manning coefficient assumed if entry less that 1.0, other assumed to Chezy method.

6               The scaling factor for friction applied as water surface falls below the bed level (only used when marshing Is active).

7               The bank friction factor (optional).  Not shown on the page but is an additional column on the right hand side.

8               The water surface friction factor (optional, only applicable) when the system has a blanket on the water surface).    Not shown on the page but is an additional column on the right hand side